This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP55 and it has a built-in EMC filter. It works at a rated power up to 22kW / 30hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 49.5kg and its dimensions are, 284mm wide, 720mm high, 315mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.

Main

Characteristic Value(s)
Device short name ATV212
Product destination Asynchronous motors
Phase 3 phase
Motor power kW 22 kW
Maximum Horse Power Rating 30 hp
Supply voltage limits 323…528 V
Supply frequency 50...60 Hz - 5...5 %
Line current 33.1 A 480 V
41.6 A 380 V
Range of Product Altivar 212
Product or Component Type Variable speed drive
Product Specific Application Pumps and fans in HVAC
Communication Port Protocol METASYS N2
LonWorks
BACnet
APOGEE FLN
Modbus
[Us] rated supply voltage 380...480 V - 15...10 %
EMC filter Class C2 EMC filter integrated
IP degree of protection IP55

Complementary

Characteristic Value(s)
Apparent power 33.2 kVA 380 V
Continuous output current 43.5 A 380 V
43.5 A 460 V
Maximum transient current 47.9 A 60 s
Speed drive output frequency 0.5…200 Hz
Speed range 1…10
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Local signalling 1 LED (red) for DC bus energized
Output voltage <= power supply voltage
Isolation Electrical between power and control
Type of cable Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.004 in² (2.5 mm²) / AWG 14
L1/R, L2/S, L3/T terminal 0.08 in² (50 mm²) / AWG 1/0
Tightening torque 5.3 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
212.4 lbf.in (24 N.m), 212 lb.in L1/R, L2/S, L3/T)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 A overload and short-circuit protection
Sampling duration 2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analog
Response time FM 2 ms +/- 0.5 ms analog
FLA, FLC 7 ms +/- 0.5 ms discrete
FLB, FLC 7 ms +/- 0.5 ms discrete
RY, RC 7 ms +/- 0.5 ms discrete
Accuracy +/- 0.6 % VIA) for a temperature variation 60 °C
+/- 0.6 % VIB) for a temperature variation 60 °C
+/- 1 % FM) for a temperature variation 60 °C
Linearity error VIA +/- 0.15 % of maximum value input
VIB +/- 0.15 % of maximum value input
FM +/- 0.2 % output
Analogue output type FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits
FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Discrete output type Configurable relay logic FLA, FLC) NO - 100000 cycles
Configurable relay logic FLB, FLC) NC - 100000 cycles
Configurable relay logic RY, RC) NO - 100000 cycles
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R)
5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R)
2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R)
2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Discrete input type F programmable 24 V DC level 1 PLC 4700 Ohm
R programmable 24 V DC level 1 PLC 4700 Ohm
RES programmable 24 V DC level 1 PLC 4700 Ohm
Discrete input logic Positive logic (source) F, R, RES), <= 5 V, >= 11 V
Negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Dielectric strength 3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Insulation resistance >= 1 mOhm 500 V DC for 1 minute
Frequency resolution Display unit 0.1 Hz
Analog input 0.024/50 Hz
Communication Service Write multiple registers (16) 2 words maximum
Read device identification (43)
Write single register (06)
Monitoring inhibitable
Read holding registers (03) 2 words maximum
Time out setting from 0.1 to 100 s
Option card Communication card LonWorks
Functionality Mid
Specific application HVAC
Discrete output number 2
Analogue input number 2
Analogue input type VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits
VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits
VIB configurable PTC probe 0...6 probes 1500 Ohm
VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Analogue output number 1
Physical interface 2-wire RS 485
Connector Type 1 open style
1 RJ45
Transmission Rate 9600 bps or 19200 bps
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, 1 stop, odd even or no configurable parity
Type of polarization No impedance
Asynchronous motor control profile Voltage/frequency ratio - Energy Saving, quadratic U/f
Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Voltage/frequency ratio, 2 points
Torque accuracy +/- 15 %
Transient overtorque 120 % of nominal motor torque +/- 10 % 60 s
Acceleration and deceleration ramps Automatic based on the load
Linear adjustable separately from 0.01 to 3200 s
Motor slip compensation Not available in voltage/frequency ratio motor control
Automatic whatever the load
Adjustable
Switching frequency 6...16 kHz adjustable
8...16 kHz with derating factor
Nominal switching frequency 8 kHz
Braking to standstill By DC injection
Network Frequency 47.5...63 Hz
Prospective line Isc 22 kA
Protection type Overheating protection drive
Thermal power stage drive
Short-circuit between motor phases drive
Input phase breaks drive
Overcurrent between output phases and earth drive
Overvoltages on the DC bus drive
Break on the control circuit drive
Against exceeding limit speed drive
Line supply overvoltage and undervoltage drive
Line supply undervoltage drive
Against input phase loss drive
Thermal protection motor
Motor phase break motor
With PTC probes motor
Width 11.2 in (284 mm)
Height 28.3 in (720 mm)
Depth 12.4 in (315 mm)
Product Weight 109.1 lb(US) (49.5 kg)

Ordering notes

  • New items are unused surplus stock and packaging condition may vary.
  • Used in Great Condition items have been previously installed or operated and are represented as serviceable used hardware.
  • Confirm the complete manufacturer part number, input voltage, output rating, motor compatibility, feedback interface, revision, and control-system requirements.

Outdwella is an independent reseller. Manufacturer names and part numbers identify compatibility and remain the property of their respective owners.

Vollständige Details anzeigen