{"product_id":"plc-atv71ld33m3z","title":"ATV71LD33M3Z Schneider Electric Altivar Lift Variable speed drive","description":"\u003cp\u003e\u003cstrong\u003eIndustrial AC servo-drive hardware supplied by Outdwella.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eATV71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct destination\u003c\/td\u003e\n\u003ctd\u003eSynchronous motors\u003cbr\u003eAsynchronous motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork number of phases\u003c\/td\u003e\n\u003ctd\u003e3 phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage limits\u003c\/td\u003e\n\u003ctd\u003e170â¦264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply frequency\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz - 5...5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e7.5 kW, 3 phases at 200...240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power hp\u003c\/td\u003e\n\u003ctd\u003e10 hp, 3 phases at 200...240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine current\u003c\/td\u003e\n\u003ctd\u003e45 A for 200 V 3 phases 7.5 kW \/ 10 hp\u003cbr\u003e39.4 A for 240 V 3 phases 7.5 kW \/ 10 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eAltivar Lift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eVariable speed drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct specific application\u003c\/td\u003e\n\u003ctd\u003eLift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariant\u003c\/td\u003e\n\u003ctd\u003eWith integrated 7-segment display terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication port protocol\u003c\/td\u003e\n\u003ctd\u003eCANopen\u003cbr\u003eModbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e200...240 V - 15...10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent power\u003c\/td\u003e\n\u003ctd\u003e16.4 kVA at 240 V 3 phases 7.5 kW \/ 10 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProspective line Isc\u003c\/td\u003e\n\u003ctd\u003e22 kA for 3 phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output current\u003c\/td\u003e\n\u003ctd\u003e33 A at 4 kHz 230 V 3 phases 7.5 kW \/ 10 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum transient current\u003c\/td\u003e\n\u003ctd\u003e44.9 A for 2 s 3 phases \/ 7.5 kW \/ 10 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed drive output frequency\u003c\/td\u003e\n\u003ctd\u003e0â¦599 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed range\u003c\/td\u003e\n\u003ctd\u003e1â¦100 for asynchronous motor in open-loop mode, without speed feedback\u003cbr\u003e1â¦50 for synchronous motor in open-loop mode, without speed feedback\u003cbr\u003e1â¦1000 for asynchronous motor in closed-loop mode with encoder feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 5 % in closed-loop mode with encoder feedback\u003cbr\u003e+\/- 15 % in open-loop mode, without speed feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient overtorque\u003c\/td\u003e\n\u003ctd\u003e170 %, +\/- 10 % for 60 s\u003cbr\u003e220 %, +\/- 10 % for 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking torque\u003c\/td\u003e\n\u003ctd\u003e30 % without braking resistor\u003cbr\u003e\u0026lt;= 150 % with braking or hoist resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003e1 LED (red) for drive voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= power supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation\u003c\/td\u003e\n\u003ctd\u003eElectrical between power and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003etype of cable for external connection\u003c\/td\u003e\n\u003ctd\u003eWithout mounting kit: 1 wire(s)IEC cable at 45 Â°C, copper 90 Â°C \/ XLPE\/EPR\u003cbr\u003eWithout mounting kit: 1 wire(s)IEC cable at 45 Â°C, copper 70 Â°C \/ PVC\u003cbr\u003eWith an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 Â°C, copper 70 Â°C \/ PVC\u003cbr\u003eWith a NEMA Type1 kit: 3 wire(s)UL 508 cable at 40 Â°C, copper 75 Â°C \/ PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003eTerminal, clamping capacity: 2.5 mmÂ², AWG 14 (AI1-\/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)\u003cbr\u003eTerminal, clamping capacity: 16 mmÂ², AWG 4 (L1\/R, L2\/S, L3\/T, U\/T1, V\/T2, W\/T3, PC\/-, PO, PA\/+, PA, PB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e3 N.m, 26.5 lb.in (L1\/R, L2\/S, L3\/T, U\/T1, V\/T2, W\/T3, PC\/-, PO, PA\/+, PA, PB)\u003cbr\u003e0.6 N.m (AI1-\/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +\/- 5 %, \u0026lt;10 A, protection type: overload and short-circuit protection\u003cbr\u003eInternal supply: 24 V DC (21â¦27 V), \u0026lt;200 A, protection type: overload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling duration\u003c\/td\u003e\n\u003ctd\u003e2 ms +\/- 0.5 ms (LI6)if configured as logic input - discrete input(s)\u003cbr\u003e2 ms +\/- 0.5 ms (LI1...LI5) - discrete input(s)\u003cbr\u003e2 ms +\/- 0.5 ms (AI1-\/Al1+) - analog input(s)\u003cbr\u003e2 ms +\/- 0.5 ms (Al2) - analog input(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003eR1A, R1B, R1C 7 ms, tolerance +\/- 0.5 ms for discrete output(s)\u003cbr\u003eR2A, R2B 7 ms, tolerance +\/- 0.5 ms for discrete output(s)\u003cbr\u003eAO1 2 ms, tolerance +\/- 0.5 ms for analog output(s)\u003cbr\u003e \u0026lt;= 100 ms in STO (Safe Torque Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.6 % (AI1-\/Al1+) for a temperature variation 60 Â°C\u003cbr\u003e+\/- 0.6 % (AI2) for a temperature variation 60 Â°C\u003cbr\u003e+\/- 1 % (AO1) for a temperature variation 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity error\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.15 % of maximum value (AI1-\/Al1+, AI2)\u003cbr\u003e+\/- 0.2 % (AO1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output type\u003c\/td\u003e\n\u003ctd\u003eAO1 software-configurable voltage: 0...10 V DC, impedance: 470 Ohm, resolution 10 bits\u003cbr\u003eAO1 software-configurable current: 0...20 mA, impedance: 500 Ohm, resolution 10 bits\u003cbr\u003eAO1 software-configurable logic output 10 V 20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output type\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay logic: (R1A, R1B, R1C) NO\/NC - 100000 cycles\u003cbr\u003eConfigurable relay logic: (R2A, R2B) NO - 100000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e3 mA at 24 V DC for configurable relay logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum switching current\u003c\/td\u003e\n\u003ctd\u003e5 A at 250 V AC on resistive load - cos phi = 1 - L\/R = 0 ms (R1, R2)\u003cbr\u003e5 A at 30 V DC on resistive load - cos phi = 1 - L\/R = 0 ms (R1, R2)\u003cbr\u003e2 A at 250 V AC on inductive load - cos phi = 0.4 - L\/R = 7 ms (R1, R2)\u003cbr\u003e2 A at 30 V DC on inductive load - cos phi = 0.4 - L\/R = 7 ms (R1, R2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input type\u003c\/td\u003e\n\u003ctd\u003eProgrammable (LI1...LI5)24 V DC, with level 1 PLC - 3500 Ohm\u003cbr\u003eSwitch-configurable (LI6)24 V DC, with level 1 PLC - 3500 Ohm\u003cbr\u003eSwitch-configurable PTC probe (LI6) - 0â¦6 probes - 1500 Ohm\u003cbr\u003eSafety input (PWR)24 V DC - 1500 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic (LI6)if configured as logic input, \u0026lt; 5 V (state 0), \u0026gt; 11 V (state 1)\u003cbr\u003eNegative logic (LI6)if configured as logic input, \u0026gt; 16 V (state 0), \u0026lt; 10 V (state 1)\u003cbr\u003ePositive logic (LI1...LI5), \u0026lt; 5 V (state 0), \u0026gt; 11 V (state 1)\u003cbr\u003eNegative logic (LI1...LI5), \u0026gt; 16 V (state 0), \u0026lt; 10 V (state 1)\u003cbr\u003ePositive logic (PWR), \u0026lt; 2 V (state 0), \u0026gt; 17 V (state 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric strength\u003c\/td\u003e\n\u003ctd\u003e2830 V DC between earth and power terminals\u003cbr\u003e4230 V DC between control and power terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 mOhm 500 V DC for 1 minute to earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency resolution\u003c\/td\u003e\n\u003ctd\u003eDisplay unit: 0.1 Hz\u003cbr\u003eAnalog input: 0.024\/50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector type\u003c\/td\u003e\n\u003ctd\u003e1 RJ45 (on front face) for Modbus\u003cbr\u003e1 RJ45 (on terminal) for Modbus\u003cbr\u003eMale SUB-D 9 on RJ45 for CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical interface\u003c\/td\u003e\n\u003ctd\u003e2-wire RS 485 for Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission frame\u003c\/td\u003e\n\u003ctd\u003eRTU for Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission rate\u003c\/td\u003e\n\u003ctd\u003e9600 bps, 19200 bps for Modbus on front face\u003cbr\u003e4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal\u003cbr\u003e20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData format\u003c\/td\u003e\n\u003ctd\u003e8 bits, 1 stop, even parity for Modbus on front face\u003cbr\u003e8 bits, odd even or no configurable parity for Modbus on terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of polarization\u003c\/td\u003e\n\u003ctd\u003eNo impedance for Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of addresses\u003c\/td\u003e\n\u003ctd\u003e1â¦247 for Modbus\u003cbr\u003e1â¦127 for CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econtrol options\u003c\/td\u003e\n\u003ctd\u003eCommunication card for Modbus TCP\u003cbr\u003eCommunication card for Fipio\u003cbr\u003eCommunication card for Modbus\/Uni-Telway\u003cbr\u003eCommunication card for Modbus Plus\u003cbr\u003eCommunication card for EtherNet\/IP\u003cbr\u003eCommunication card for DeviceNet\u003cbr\u003eCommunication card for Profibus DP\u003cbr\u003eCommunication card for Profibus DP V1\u003cbr\u003eCommunication card for Interbus-S\u003cbr\u003eCommunication card for CC-Link\u003cbr\u003eInterface card for encoder\u003cbr\u003eI\/O extension card\u003cbr\u003eController inside programmable card\u003cbr\u003eOverhead crane card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input number\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output number\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input number\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input type\u003c\/td\u003e\n\u003ctd\u003eAI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits\u003cbr\u003eAI1-\/Al1+ bipolar differential voltage: +\/- 10 V DC 24 V max, resolution 11 bits + sign\u003cbr\u003eAI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output number\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod of access\u003c\/td\u003e\n\u003ctd\u003eSlave CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsynchronous motor control profile\u003c\/td\u003e\n\u003ctd\u003eFlux vector control without sensor, 2 points\u003cbr\u003eVoltage\/frequency ratio, 2 points\u003cbr\u003eVoltage\/frequency ratio - Energy Saving, quadratic U\/f\u003cbr\u003eFlux vector control without sensor, ENA (energy Adaptation) system\u003cbr\u003eVoltage\/frequency ratio, 5 points\u003cbr\u003eFlux vector control with sensor, standard\u003cbr\u003eFlux vector control without sensor, standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronous motor control profile\u003c\/td\u003e\n\u003ctd\u003eVector control without sensor, standard\u003cbr\u003eVector control with sensor, standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceleration and deceleration ramps\u003c\/td\u003e\n\u003ctd\u003eLinear adjustable separately from 0.01 to 9000 s\u003cbr\u003eAutomatic adaptation of ramp if braking capacity exceeded, by using resistor\u003cbr\u003eS, U or customized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor slip compensation\u003c\/td\u003e\n\u003ctd\u003eSuppressable\u003cbr\u003eAdjustable\u003cbr\u003eAutomatic whatever the load\u003cbr\u003eNot available in voltage\/frequency ratio (2 or 5 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd\u003e1...16 kHz adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal switching frequency\u003c\/td\u003e\n\u003ctd\u003e8 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork frequency\u003c\/td\u003e\n\u003ctd\u003e47.5...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eOverheating protection: drive\u003cbr\u003eThermal protection: drive\u003cbr\u003eShort-circuit between motor phases: drive\u003cbr\u003eInput phase breaks: drive\u003cbr\u003eOvercurrent between output phases and earth: drive\u003cbr\u003eOvervoltages on the DC bus: drive\u003cbr\u003eBreak on the control circuit: drive\u003cbr\u003eAgainst exceeding limit speed: drive\u003cbr\u003eLine supply undervoltage: drive\u003cbr\u003eLine supply overvoltage: drive\u003cbr\u003eAgainst input phase loss: drive\u003cbr\u003eThermal protection: motor\u003cbr\u003eMotor phase break: motor\u003cbr\u003ePower removal: motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eOrdering notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNew items are unused surplus stock and packaging condition may vary.\u003c\/li\u003e\n\u003cli\u003eUsed in Great Condition items have been previously installed or operated and are represented as serviceable used hardware.\u003c\/li\u003e\n\u003cli\u003eConfirm the complete manufacturer part number, input voltage, output rating, motor compatibility, feedback interface, revision, and control-system requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eOutdwella is an independent reseller. Manufacturer names and part numbers identify compatibility and remain the property of their respective owners.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"New","offer_id":53586316460216,"sku":"ATV71LD33M3Z","price":4189.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/1556\/9848\/files\/ATV71LD33M3Z.jpg?v=1781320054","url":"https:\/\/www.outdwella-vip.com\/es\/products\/plc-atv71ld33m3z","provider":"Outdwella","version":"1.0","type":"link"}