{"product_id":"plc-atv212wd11n4c","title":"ATV212WD11N4C Schneider","description":"\u003cp\u003e\u003cstrong\u003eIndustrial AC servo-drive hardware supplied by Outdwella.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThis Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP55 and it has a built-in EMC filter. It works at a rated power up to 11kW \/ 15hp and a rated voltage from 380V to 480V AC. Its design allows for up to 70% reduction in energy consumption compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 36.5kg and its dimensions are, 290mm wide, 560mm high, 315mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC\/EN 61800-5-1 and IEC\/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+\/- 10 Â°) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is labeled Green Premium and complies with environmental protection directives such as RoHS, WEEE, etc.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eATV212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct destination\u003c\/td\u003e\n\u003ctd\u003eAsynchronous motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Horse Power Rating\u003c\/td\u003e\n\u003ctd\u003e15 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage limits\u003c\/td\u003e\n\u003ctd\u003e323â¦528 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply frequency\u003c\/td\u003e\n\u003ctd\u003e50...60 Hz - 5...5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine current\u003c\/td\u003e\n\u003ctd\u003e21.1 A 380 V\u003cbr\u003e16.7 A 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eAltivar 212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eVariable speed drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Specific Application\u003c\/td\u003e\n\u003ctd\u003ePumps and fans in HVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port Protocol\u003c\/td\u003e\n\u003ctd\u003eBACnet\u003cbr\u003eMETASYS N2\u003cbr\u003eLonWorks\u003cbr\u003eModbus\u003cbr\u003eAPOGEE FLN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Us] rated supply voltage\u003c\/td\u003e\n\u003ctd\u003e380...480 V - 15...10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC filter\u003c\/td\u003e\n\u003ctd\u003eClass C1 EMC filter integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent power\u003c\/td\u003e\n\u003ctd\u003e17.1 kVA 380 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous output current\u003c\/td\u003e\n\u003ctd\u003e22.5 A 380 V\u003cbr\u003e22.5 A 460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum transient current\u003c\/td\u003e\n\u003ctd\u003e24.8 A 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed drive output frequency\u003c\/td\u003e\n\u003ctd\u003e0.5â¦200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed range\u003c\/td\u003e\n\u003ctd\u003e1â¦10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 % of nominal slip 0.2 Tn to Tn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003e1 LED (red) for DC bus energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= power supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eElectrical between power and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of cable\u003c\/td\u003e\n\u003ctd\u003eWithout mounting kit 1 IEC cable 113 Â°F (45 Â°C), copper 90 Â°C \/ XLPE\/EPR\u003cbr\u003eWithout mounting kit 1 IEC cable 113 Â°F (45 Â°C), copper 70 Â°C \/ PVC\u003cbr\u003eWith UL Type 1 kit 3 UL 508 cable 104 Â°F (40 Â°C), copper 75 Â°C \/ PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003eVIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.004 inÂ² (2.5 mmÂ²) \/ AWG 14\u003cbr\u003eL1\/R, L2\/S, L3\/T terminal 0.02 inÂ² (10 mmÂ²) \/ AWG 6\u003cbr\u003eU\/T1, V\/T2, W\/T3 terminal 0.02 inÂ² (16 mmÂ²) \/ AWG 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e5.3 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)\u003cbr\u003e15.05 lbf.in (1.7 N.m), 15 lb.in L1\/R, L2\/S, L3\/T)\u003cbr\u003e26.6 lbf.in (3 N.m), 26.5 lb.in U\/T1, V\/T2, W\/T3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eInternal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +\/- 5 %, \u0026lt;10 A overload and short-circuit protection\u003cbr\u003eInternal supply 24 V DC 21â¦27 V), \u0026lt;200 A overload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling duration\u003c\/td\u003e\n\u003ctd\u003e2 ms +\/- 0.5 ms F discrete\u003cbr\u003e2 ms +\/- 0.5 ms R discrete\u003cbr\u003e2 ms +\/- 0.5 ms RES discrete\u003cbr\u003e3.5 ms +\/- 0.5 ms VIA analog\u003cbr\u003e22 ms +\/- 0.5 ms VIB analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003eFM 2 ms +\/- 0.5 ms analog\u003cbr\u003eFLA, FLC 7 ms +\/- 0.5 ms discrete\u003cbr\u003eFLB, FLC 7 ms +\/- 0.5 ms discrete\u003cbr\u003eRY, RC 7 ms +\/- 0.5 ms discrete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.6 % VIA) for a temperature variation 60 Â°C\u003cbr\u003e+\/- 0.6 % VIB) for a temperature variation 60 Â°C\u003cbr\u003e+\/- 1 % FM) for a temperature variation 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity error\u003c\/td\u003e\n\u003ctd\u003eVIA +\/- 0.15 % of maximum value input\u003cbr\u003eVIB +\/- 0.15 % of maximum value input\u003cbr\u003eFM +\/- 0.2 % output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output type\u003c\/td\u003e\n\u003ctd\u003eFM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits\u003cbr\u003eFM switch-configurable current 0...20 mA 970 Ohm 10 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output type\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay logic FLA, FLC) NO - 100000 cycles\u003cbr\u003eConfigurable relay logic FLB, FLC) NC - 100000 cycles\u003cbr\u003eConfigurable relay logic RY, RC) NO - 100000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e3 mA 24 V DC configurable relay logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum switching current\u003c\/td\u003e\n\u003ctd\u003e5 A 250 V AC resistive cos phi = 1 L\/R = 0 ms FL, R)\u003cbr\u003e5 A 30 V DC resistive cos phi = 1 L\/R = 0 ms FL, R)\u003cbr\u003e2 A 250 V AC inductive cos phi = 0.4 L\/R = 7 ms FL, R)\u003cbr\u003e2 A 30 V DC inductive cos phi = 0.4 L\/R = 7 ms FL, R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input type\u003c\/td\u003e\n\u003ctd\u003eF programmable 24 V DC level 1 PLC 4700 Ohm\u003cbr\u003eR programmable 24 V DC level 1 PLC 4700 Ohm\u003cbr\u003eRES programmable 24 V DC level 1 PLC 4700 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic (source) F, R, RES), \u0026lt;= 5 V, \u0026gt;= 11 V\u003cbr\u003eNegative logic (sink) F, R, RES), \u0026gt;= 16 V, \u0026lt;= 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric strength\u003c\/td\u003e\n\u003ctd\u003e3535 V DC between earth and power terminals\u003cbr\u003e5092 V DC between control and power terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 1 mOhm 500 V DC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency resolution\u003c\/td\u003e\n\u003ctd\u003eDisplay unit 0.1 Hz\u003cbr\u003eAnalog input 0.024\/50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Service\u003c\/td\u003e\n\u003ctd\u003eMonitoring inhibitable\u003cbr\u003eWrite single register (06)\u003cbr\u003eTime out setting from 0.1 to 100 s\u003cbr\u003eWrite multiple registers (16) 2 words maximum\u003cbr\u003eRead device identification (43)\u003cbr\u003eRead holding registers (03) 2 words maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption card\u003c\/td\u003e\n\u003ctd\u003eCommunication card LonWorks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific application\u003c\/td\u003e\n\u003ctd\u003eHVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output number\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input number\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue input type\u003c\/td\u003e\n\u003ctd\u003eVIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits\u003cbr\u003eVIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits\u003cbr\u003eVIB configurable PTC probe 0...6 probes 1500 Ohm\u003cbr\u003eVIA switch-configurable current 0...20 mA 250 Ohm 10 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output number\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical interface\u003c\/td\u003e\n\u003ctd\u003e2-wire RS 485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e1 RJ45\u003cbr\u003e1 open style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e9600 bps or 19200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission frame\u003c\/td\u003e\n\u003ctd\u003eRTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of addresses\u003c\/td\u003e\n\u003ctd\u003e1â¦247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData format\u003c\/td\u003e\n\u003ctd\u003e8 bits, 1 stop, odd even or no configurable parity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of polarization\u003c\/td\u003e\n\u003ctd\u003eNo impedance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsynchronous motor control profile\u003c\/td\u003e\n\u003ctd\u003eVoltage\/frequency ratio, 2 points\u003cbr\u003eVoltage\/frequency ratio - Energy Saving, quadratic U\/f\u003cbr\u003eFlux vector control without sensor, standard\u003cbr\u003eVoltage\/frequency ratio, automatic IR compensation (U\/f + automatic Uo)\u003cbr\u003eVoltage\/frequency ratio, 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient overtorque\u003c\/td\u003e\n\u003ctd\u003e120 % of nominal motor torque +\/- 10 % 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceleration and deceleration ramps\u003c\/td\u003e\n\u003ctd\u003eLinear adjustable separately from 0.01 to 3200 s\u003cbr\u003eAutomatic based on the load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor slip compensation\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003cbr\u003eNot available in voltage\/frequency ratio motor control\u003cbr\u003eAutomatic whatever the load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd\u003e6...16 kHz adjustable\u003cbr\u003e12...16 kHz with derating factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal switching frequency\u003c\/td\u003e\n\u003ctd\u003e12 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking to standstill\u003c\/td\u003e\n\u003ctd\u003eBy DC injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e47.5...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProspective line Isc\u003c\/td\u003e\n\u003ctd\u003e22 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eOverheating protection drive\u003cbr\u003eThermal power stage drive\u003cbr\u003eShort-circuit between motor phases drive\u003cbr\u003eInput phase breaks drive\u003cbr\u003eOvercurrent between output phases and earth drive\u003cbr\u003eOvervoltages on the DC bus drive\u003cbr\u003eBreak on the control circuit drive\u003cbr\u003eAgainst exceeding limit speed drive\u003cbr\u003eLine supply overvoltage and undervoltage drive\u003cbr\u003eLine supply undervoltage drive\u003cbr\u003eAgainst input phase loss drive\u003cbr\u003eThermal protection motor\u003cbr\u003eMotor phase break motor\u003cbr\u003eWith PTC probes motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e11.4 in (290 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e22.05 in (560 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e12.4 in (315 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e80.5 lb(US) (36.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eOrdering notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNew items are unused surplus stock and packaging condition may vary.\u003c\/li\u003e\n\u003cli\u003eUsed in Great Condition items have been previously installed or operated and are represented as serviceable used hardware.\u003c\/li\u003e\n\u003cli\u003eConfirm the complete manufacturer part number, input voltage, output rating, motor compatibility, feedback interface, revision, and control-system requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eOutdwella is an independent reseller. Manufacturer names and part numbers identify compatibility and remain the property of their respective owners.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"New","offer_id":53586316918968,"sku":"ATV212WD11N4C","price":2595.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/1556\/9848\/files\/ATV212WD11N4C.jpg?v=1781320062","url":"https:\/\/www.outdwella-vip.com\/es\/products\/plc-atv212wd11n4c","provider":"Outdwella","version":"1.0","type":"link"}